Limit Anahtarlar

Automatic changover switch 50A

Marka: Zhejiang Smico Electric Power Equipment Co., LTD.
Price on request

Send a free RFQ and get the supplier's best price.

Asgari Sipariş10 Unit
KoşulNew
GarantiYES
Kaydet Share

Teklif İste

Free · No obligation · Supplier replies on WhatsApp

Trade with confidence on Abraa

Abraa güvenli ticaret sistemlerini kullanarak güvenli ve emniyetli ödemeler

Learn more

Supplier verification not completed

Pay only through Abraa to stay protected. Never pay a supplier by direct transfer.

Learn more

Secure Payment

Pay through Abraa, never by direct transfer to a supplier.

Product Inspection

Book a check before shipping to confirm quality and quantity.

Alıcı Koruması

Get support and refunds if goods arrive not as described.

Verified Suppliers

Licence, address and on-site checks by the Abraa team.

Ürün Özellikleri

Zhejiang Smico Electric Power Equipment Co., LTD.
New
YES

Product Descriptions

Product Outline
  SGLD automatic change-over switch(ATSE)integrates switch and logic control,thus it is not necessary to provide external controller. This truly electromechanically integrated automatic change-over switch has the following functions such as voltage detection,frequency detection,communication interface,electrical and mechanical interlocking etc.,so,automatic control,electrical remote control and emerge- ncy manual control can be performed.
  The operation is carried out through the logic control board,which gives various commands to control the motor and gear-box.The motor drives the accelerator which can take switch-spring power accumulating and instantaneous release,swiftly turns making and breaking the circuit or makes circuit switching.The visible operation status can help you to perform safe separation,increasing extremely the various electrical and mechanical performance.
  Which the shell of switch SGLD is made of different materials:its control section is made of metal,but the switching section is made of glass-fibre unsaturated polyester resin,having stronger dielectric property and protective capability as well as safe operation performance.
  This kind of switch is suitable for the automatic changeover of the main power source and the secondary power source of the power supply system of the automatic change-over and safe separation of the 2 sets of load-equipment.
  This kind of switch has a beautiful,novel and simple structure,a small volume but complete functions,being the best choice among congeneric of products.
  SGLD Series had been already passed the detection of EMC.
SGLD-100/4~380V In 50A
  The automatic change-over switch,the initial heat electric current 100 amperes,rated AC voltage 380V,the nominal current 50 amperes,4poles (3poles+break neutrality pole)suitable for city electricity-city electricity system’s automatic switch and self-reset.
Conform Standard
  SGLD Series Automatic Change-Over Switch Complies With The Following Standards;
Interanational Standard
  IEC60947-1(1998)《Low-voltage switchgear and controlgear,part one:General Rules》
  IEC60947-3(1999)《Low-voltage switchgear and controlgear,switches,disconnetors,switch-disconnectors and fuse-conbination nuits》
  IEC60947-6(1999)《Low-voltage switch equipment and control equipment multi-function-swtch automatic change-over switch electrical device》
National Standard:
  GB/T14048.1-2002《Low-voltage switchgear and controlgear,part one:General Rules》
  GB14048.3-2002《Low-voltage switchgear and controlgear,switches,disconneetors,switch-disconnectors and fuse-conbination units》
  GB14048.11-2002《Low-voltage switch equipment and control equipment multi-function-switch automatic changeover switch electrical device》
Main Technical Parameters
1、SGLD-100~1600A series automatic change-over switch electrical properties and mechanical properies

Conventional thermal current lth A

100A 160A
Rated current ln(A) 20A 40A 63A 80A 100A 125A 160A
Rated impulse withstand voltage Ui(A) 500 500 500 500 500 500 500
Dielectric strength(V) 5000 5000 5000 5000 5000 5000 5000
Rated surge-resistant voltage Uimp kV(installed category IV) 8 8 8 8 8 8 8
Rated Working current le(A) 380A AC-31 20 40 63 80 100 125 160
AC-33 20 32 40 63 80 125 160
AC-35 20 40 63 80 100 125 160
220A DC-31 20 40 63 80 100 125 160
DC-33 20 32 40 63 80 100 125
DC-35 20 40 63 80 100 125 160
Motor power P(380V)kW 10 20 25 30 32 60 80
Rated short-time withstand current(kA Rms)0.1S/1S 9/5 9/5 9/5 9/5 9/5 20/10 20/10
Rated breaking capbility(A Rms)AC33 380V 160 320 500 640 800 1000 1000
Rated making capability(A Rms)AC33 380V 200 400 630 800 1000 1250 1250
Rated short-current making capability lcm(kA peak value) 8 8 10 10 10 12 12
Mechanical durability(number of cyclic operation) 8000 8000 8000 8000 8000 5000 5000
Electric durability COSφ=0.65 AC33 1500 1500 1500 1500 1500 1000 1000
Change-oner time I-0-II 或 II-0-I (s)
I-0 或 II-0 (s)
0.5
0.3
0.5
0.3
0.5
0.3
0.5
0.3
0.5
0.3
1.0
0.6
1.0
0.6
Power wer consumption of electrical control 24V(DC)(w) 50 50 50 50 50 75 75
220V(AC)(w) 50 50 50 50 50 75 75
Moment of operation(Nm) 15 15 15 15 15 22 22
Weight(kg) 3poles           8.2 8.2
4poles 4.2 4.3 4.4 4.5 4.5 8.7 8.7



Conventional thermal current lth A

250A 630A 1600A 3200A
Rated current ln(A) 200A 250A 400A 630A 800A 1000A 1250A 1600A 2000A 2000A 3200A
Rated impulse withstand voltage Ui(A) 500 500 500 500 500 500 500 500 500 500 500
Dielectric strength(V) 5000 5000 8000 8000 10000 10000 10000 10000 10000 10000 10000
Rated surge-resistant voltage Uimp kV(installed category IV) 8 8 12 12 12 12 12 12 12 12 12
Rated Working current le(A) 380A AC-31 200 250 400 630 800 1000 1250 1600 2000 2500 3200
AC-33 200 250 340 536 800 1000 1000 1600 1250 1250 1250
AC-35 200 250 400 630 800 1000 1250 1600 2000 2000 2500
220A DC-31 200 250 400 630 800 1000 1250 1600      
DC-33 160 200 315 500              
DC-35 200 250 400 500 800 1000 1250 1600      
Motor power P(380V)kW 100 132 220 280              
Rated short-time withstand current(kA Rms)0.1S/1S 25/12 25/12 40/20 50/25 90/50 90/50 90/50 90/50 90/50 90/50 95/50
Rated breaking capbility(A Rms)AC33 380V 1600 1600 3200 3200 6400 8000 10000 12800 16000 20000 25600
Rated making capability(A Rms)AC33 380V 2000 2000 4000 4000 8000 10000 12500 16000 20000 25000 32000
Rated short-current making capability lcm(kA peak value) 17 17 30 30              
Mechanical durability(number of cyclic operation) 5000 5000 4000 4000 2500 2500 2500 2500 1500 1500 1500
Electric durability COSφ=0.65 AC33 1000 1000 500 500 500 500 500 500 300 300 300
Change-oner time I-0-II 或 II-0-I (s)
I-0 或 II-0 (s)
1.1
0.7
1.1
0.7
1.2
0.8
1.2
0.8
1.2
0.8
1.2
0.8
1.2
0.8
1.2
0.8
2.4
1.6
2.4
1.6
2.4
1.6
Power wer consumption of electrical control 24V(DC)(w) 75 75 90 90 90 90 90 90 120 120 120
220V(AC)(w) 75 75 90 90 90 90 90 90 120 120 120
Moment of operation(Nm) 30 30 45 45 55 55 55 60 95 95 95
Weight(kg) 3poles 10.4 10.4 17.8 19 28 31 31 34      
4poles 11.3 11.3 20.2 22 32 36 40 49 98 98 135



Performance and characteristic
  It adopted double complex contact,horizontal and vertical type framework,Micro motor pre-saving and Micro electronic control technical,basically,it have come to"Zero"arc(No Arc Chute);
  It adopt reliable machine interlock and electric interlock,the elecutive union parts adopt independency overload disconnect switch,it makes more reliable and safety;
  Adopt"Zero"technique,it can force to set"zero"under emergenncy situation(break off two way power supply at the same time),meet the requirement of fire protection linkage;
  Operate overload disconnect switch change over adopt singleness electromotor drive,switch over smooth and reliable,no noise,little wallop;
  Operate machine drive motor use only under the executive overload disconnect switch change over instantaneouse current across,outstanding energy saving;
  Perform overload disconnect switch with mechanism interlock device,it ensure the common use ,standby power working reliable and not interference;
  Distinct On and Off position indicator/padlock functionetc.,safe reallze the disconnect between electric power and overload;
  High security,high automatization,high reliable,use life more than 5000 times;
  Machine & Electricity perfect desigh,On-Off changeover nicety、agility/smooth,adopt interm、national advanced logical control technique,high anti-interference and nointerference outside;
  It include main power close,standby power separate;main power separate;standby power close;main、standby power all break off and steady working(I-0-II).
  Easy installation,control loop adopt terminal connection and insert.
  Four kind of operation function;emergency manual operation、electromotion remote control operation、automatic control state emergency off opeartion 、automatic control operation. 
Product Usage
  SGLD Series automatic change over switch mainly suitable for distribution or electromotor network,which under AC 50Hz,rated voltage 380V,rated voltage DC220V,rated current 16~1600A,main power andstandby power or mutual standby power change over system or city power and generator group overload switch-over system or city power and generator group overload switch-over.At the same time,it can operated under un-frequency On and Off cicruit act as disconnector.
  Such products are widely used at the field of lmportant Power supply site,which transport,distribution power supply system and automatization.system.for Fire Proection、Band、Building etc.,which doesn’t allowed power off



Cortrol Characteristic
  The switch has 3 poles or 4 poles (3 poles+on or off neutral pole).
  27 current grades can be divided into 16A、20A、25A、32A、40A、50A、63A、80A、100A、125A、160A、200A、225A、250A、315A、350A、400A、450A、500A、630A、800A、1000A、1250A、1600A、2000A、2500A、3200A.
  Basic Type:Mainstandby power,self-cast,self reset.
  Intelligent type:Four kind of working patterns for selection
  1.Self-switch and self-reset:suitable in the city electricity-city electricity.,two circuit power,three phase of lack,over and low voltage examinaiton.
  2.Self-switch,not self-reset:suitable in the city electricity-city electricity.,two circuit power,three phase of lack,over and low voltage examinaiton.
  3.City electrical Generator:suitable in the city electricity-kerosene engine,self-switch and self-reset two circuit power three phase lack,over voltage examination.
  4.Instrument display:only for show.
  Basic type switch control characteristic
  1.Suitable in the two circuit of main and prepare electrical power,self-switch and self-reset;
  2.External connection carries on the function expansion.
  Suitable in the two circuit of main and prepare electrical power
  Intelligent type switch control characteristic;
  1、Self switch and self reset
  when the main when the main power supply circuit loop breaks down(lack phase,over voltage)the switch(to be possible set 0~999S)after transformation time delay T1 to automatically changeover into the spare power supply circuit loop.
  When the main electrical power supply loop recover normal,switch return time delay T2(may set 0~999S)automatically back to the main power loopl
  2.Self switch no self reset
  Suitable in the two circuit city electricity mutually backup system
  When I route power circuit failure(lack phase,over voltage);The switch(may set 0~999S)after transformation time delay T1 automatically changeover into II Road power circuit;When the I route power circit restores and become normal,the switch does not returns I Road,only then in route II power failure,the switch returns time delay T2(may set 0~999S)to automatically returns I Road power circuit.
  3.City electrical generator
  Is suitable supplies power primarily in the city electricity,the power set for the spare power supply system.When the city electricity breaks don,the switch controller first sends cut the start kerosene engine signal,the switch(i.e.Warm machine time adjustable 0~, 999S)transfer automatically after transformation time delay T1 into the kerosene engine power supply retrun route.I When the city electricity restores is normal,the switch after returns by the delay T2(may set0~999S)automatically changeover returns to the city electricity power supply,after then cold machine time delay T3(may set0~999S)again,the controller sends out the shutting down kerosene engine signal.The city electricity,the kerosene engine have three-phase lack,three-phase low and over voltage examination function etc.



The above-mentioned 4 models having:
①.The function of automation,electric control and hand control.
②.Delay-time 0.5s,detection signal,to prevent error action.
③.Remote control "0" position.
④.The key switch to select control modes.
⑤.The switch can all be proviede with RS-485 communication.This can be provided according to the requirements of the user.
Operation Environment
SGLD automatic changing-over is olation switch can work reliably under the following conditions:
◎Height above sea level does not exceed 2,000m;
◎Ambient temperature is not higher than 40℃ and not lower than -5℃;
◎Relative humidity is not larger than 95%;
◎No explosive dangerous medium environment;
 No rain and snow attack environment;
 Note:if the load isolation switch is expected to be used in the condition that the ambient temperature is higher than +40℃ or is lower than -5℃~-45℃,customers should inform to the manufactory.
City power-oil machine automatic cut over schematic drawing

Henüz Bir Geri Dönüş Bulunmamakta
Please login to review this product.
close image\
Product Added To Container Successfuly !
An error occured while adding the product
please try again later !
You can't order less than 10
Abraa'ya hoş geldiniz!
En son ürünleri, en iyi teklifleri ve güncel fırsatları içeren Abraa Bültenini doğrudan e-postanıza almak için şimdi abone olun!
Loading…